INSTALLATION & SERVICE MANUAL FOR PROFESSIONALS
Installation: Location Considerations
en
Installation
Location Considerations
Use of an appliance outside the specied conditions and contrary to its intended use will re-
sult in loss of all warranty claims. The warranty is limited to devices installed solely by trained
and certied personnel.
The following should be considered when selecting the appropriate location for installation:
Conrm whether installation mode A (default) or B (optional) is possible at the installation
site. If mode B is preferred, follow the replacement procedure on page 26.
Note: The function for switching between modes A and B allows the duct pair (outside or
inside) to be directed towards the unit from the left OR right according to the construc-
tion of the building and room. See the dierence between the two modes in the “General
description on page 17.
HCV units are designed to be installed in dry environments with temperatures of >12°C,
in utility rooms or similar heated rooms.
Provide additional space to ensure proper installation and service access (see “Positioning
the device on page 31).
Ensure that the wall structure is sucient to support the weight of the unit regardless of
the wall bracket type.
Minimum space required for service access:
Top view Front View
Min.
5 mm
Min.
5 mm
Min. 800 mm
Min.
500 mm
Min.
300 mm
Min.
500 mm