Electrical and Gas Leak Checks
ALL WIRING MUST BE INSTALLED BY A
LICENSED ELECTRICIAN AND COMPLY
WITH LOCAL, STATE, AND NATIONAL
ELECTRICAL CODES.
WARNING - RISK OF
ELECTRICAL SHOCK
If electrical leakage is detected, turn o the
unit immediately and call a licensed electri-
cian to find and resolve the cause of
the leakage.
IF ELECTRICAL LEAKAGE
IS DETECTED
Electrical Safety Checks
After installation is complete, confirm that all
electrical wiring has been installed in accor-
dance with local and national regulations,
and according to the installation manual.
AFTER PERFORMING
GAS LEAK CHECKS
After confirming that all of the refrigerant
pipe connections points DO NOT leak,
replace the valve cover on the outside unit
and wrap and insulate the piping connections
of the indoor unit.
A: Low pressure stop valve
B: High pressure stop valve
C & D: Indoor unit flare nuts
Gas Leak Checks
There are two dierent methods to check for
gaseous leaks. Use Fig. 8.1 below as a guide
for the critical points to check for leaks.
Soap and Water Method
Using a soft brush or spray bottle, apply a
soapy water solution to all of the pipe con-
nection points of the indoor and outdoor
units, watching to see if any bubbles form.
The presence of bubbles indicates there is a
leak.
Leak Detector Method
If using a leak detector, refer to the device' s
operation/instruction manual for proper
usage instructions.
BEFORE TEST RUN
Check Grounding Work
Measure grounding resistance by visual
detection and with a grounding resistance
tester. Grounding resistance must be less
than 0.1Ω.
DURING TEST RUN
Check for Electrical Leakage
During the Test Run, use an electroprobe and
multimeter to perform a comprehensive
electrical leakage test.
NOTE: This may not be required for some
locations in North America.
NOTE: This may not be required for some
locations in North America.