Daikin RXM50A5V1B handleiding

80 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 51 van 80
9 | Electrical installation
Installer reference guide
51
RXA-B8, RXM-A(9), ARXM-A(9), RXP-N9, RXF-D(9), ARXF-A(9), RZAG-B
R32 split series
4P766272-2 – 2024.01
2
1
1
2 Strip insulation (20mm) from the wires.
a b
a Strip wire end to this point
b An excessive strip length may cause electrical shock or leakage
3 Open the wire clamp.
4 Connect the interconnection cable and power supply as follows:
f
50 Hz
220-240 V
a b
c d e
a Interconnection cable
b Power supply cable
c Circuit breaker (field provided fuse with rating according to the model name plate)
d Residual current device
e Power supply
f Earth
1 2 3
5 Tighten the terminal screws securely. We recommend using a Phillips
screwdriver.
6 Install the service cover.
7 Install the switch box cover.