Daikin DSR1 handleiding
Handleiding
Je bekijkt pagina 19 van 52

19
Technician - Electrical connections
System 3 (1 collector, 1 storage tank, 1 solid fuel boiler)
F1
A3
A1
F3
F4
F2
A2
Outputs
A1 Collector pump (speed control)
A2 Feeding pump for solid fuel boiler
A3 Additional relay, function can be freely assigned
Inputs
F1 Collector sensor
F2 Solid fuel boiler sensor
F4
Tank bottom sensor
or max. temperature monitoring A1 (if F3 is not installed)
Optional
F3
Tank top sensor,
Max. temperature monitoring A1
or reference sensor for reheating
F5 Additional sensor
Switching conditions A1
ON: Temp
F1
- Temp
F4
> P30 and Temp
F1
> P40,
OFF: Temp
F1
- Temp
F4
< P31 or Temp
F1
< P41.
Switching conditions A2
ON: Temp
F2
- Temp
F4
> P32 and Temp
F2
> P43 + 5 K,
OFF: Temp
F2
- Temp
F4
< P33 or Temp
F2
< P43.
System 4 (2 collectors, 1 storage tank, 2 collector pumps)
F1
A3
A3
F2
A1
A2
F3
F4
Outputs
A1 Collector pump 1
A2 Collector pump 2
Optional
A3 Additional relay, function can be freely assigned
Inputs
F1 Collector 1 sensor
F2 Collector 2 sensor
F4 Tank bottom sensor
Optional
F3 Tank top sensor
F5 Additional sensor
Switching conditions A1
ON: Temp
F1
- Temp
F4
> P30 and Temp
F1
> P40,
OFF: Temp
F1
- Temp
F4
< P31 or Temp
F1
< P41.
Switching conditions A2
ON: Temp
F2
- Temp
F4
> P32 and Temp
F2
> P40,
OFF: Temp
F2
- Temp
F4
< P33 or Temp
F2
< P41.