CYP MED-PJ-8320 handleiding
Handleiding
Je bekijkt pagina 45 van 92

40
cause compatibility issues with certain sources. If this happens, it is
recommended to switch to one of the 3 default EDIDs for maximum
compatibility.
4) User 1~4 Update: To update any of the unit’s 4 User EDIDs, click the
“Choose File” button to open the le selection window and then select
the EDID le (*.bin format) located on your local PC. After selecting
the le, click the “Update” button to begin the EDID upload process.
6.4.7 HDCP Mode Tab
This tab provides control over the HDCP settings for all inputs that
support HDCP.
1) HDCP Mode Input 2 & 3: Use the dropdown to select the HDCP
behavior for each input.
Note: Input 1’s SDI port does not support HDCP.
■
HDCP Support O: Completely disables support for HDCP on that
input.
■
Refer to Source: Makes the input port support the same HDCP
version as required by the connected source.
■
Refer to Display: Makes the input support the HDCP version of
the currently connected displays.
Bekijk gratis de handleiding van CYP MED-PJ-8320, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | CYP |
| Model | MED-PJ-8320 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 6462 MB |







