CYP MED-PJ-8320 handleiding

92 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 45 van 92
40
cause compatibility issues with certain sources. If this happens, it is
recommended to switch to one of the 3 default EDIDs for maximum
compatibility.
4) User 1~4 Update: To update any of the unit’s 4 User EDIDs, click the
“Choose File” button to open the le selection window and then select
the EDID le (*.bin format) located on your local PC. After selecting
the le, click the “Update button to begin the EDID upload process.
6.4.7 HDCP Mode Tab
This tab provides control over the HDCP settings for all inputs that
support HDCP.
1) HDCP Mode Input 2 & 3: Use the dropdown to select the HDCP
behavior for each input.
Note: Input 1’s SDI port does not support HDCP.
HDCP Support O: Completely disables support for HDCP on that
input.
Refer to Source: Makes the input port support the same HDCP
version as required by the connected source.
Refer to Display: Makes the input support the HDCP version of
the currently connected displays.