COMMAND
Description and Parameters
set_vw_pos N1 N2 {N3}
Set the displays position within the video wall. (Cannot exceed the
video wall’s horizontal and vertical display count.)
N1 = 0~15 [Row]
N2 = 0~15 [Column]
N3 = 0~255 [Target Rx {Optional}]
Note: The Target Rx number can be obtained by turning on the Video
Wall OSD. Omitting N3 makes the settings global to all receivers.
set_vw_bc N1 N2 N3 N4 {N5}
Set the video wall display’s bezel compensation values.
N1 = 0~99999 [Video width]
N2 = 0~99999 [Total display width]
N3 = 0~99999 [Video height]
N4 = 0~99999 [Total display height]
N5 = 0~255 [Target Rx {Optional}]
Note: The Target Rx number can be obtained by turning on the Video
Wall OSD. Omitting N3 makes the settings global to all receivers.
set_vw_hscale N1 {N2}
Set the video wall display’s horizontal zoom amount.
N1 = 0~99999 [Zoom amount in 1 pixel units]
N2 = 0~255 [Target Rx {Optional}]
Note: The Target Rx number can be obtained by turning on the Video
Wall OSD. Omitting N3 makes the settings global to all receivers.