29
COMMAND
Description and Parameters
set_vw_vscale N1 {N2}
Set the video wall display’s vertical zoom amount.
N1 = 0~99999 [Zoom amount in 1 pixel units]
N2 = 0~255 [Target Rx {Optional}]
Note: The Target Rx number can be obtained by turning on the Video
Wall OSD. Omitting N3 makes the settings global to all receivers.
set_vw_shift N1 N2 {N3}
Set the video wall display’s output shift.
Available values for N1:
U [Shift up]
D [Shift down]
L [Shift left]
R [Shift right]
N2 = 0~80000 [Pixel shift. Must be in increments of
8.]
N3 = 0~255 [Target Rx {Optional}]
Note: The Target Rx number can be obtained by turning on the Video
Wall OSD. Omitting N3 makes the settings global to all receivers.