To congure a condition test, select the Condition Port to read a
value from, select a logical comparison expression, and then select
a static value to use for the comparison.

For example, if the following choices are made:

Cond Port [1], If [=], Value [42]

Then the unit will check the value of Condition Port #1 and if the
value stored there equals “42” then the test will return “true” and the
macro step will execute. If the stored value is any other number, it
will return “false” and the macro step will be skipped.
6.6.2 Extension Macro 1~3 Tabs
Click on any of the three “Extension Macro tabs to execute/edit the
24 additional software-only macro buttons. These macros can only be
activated via the WebGUI or Telnet. Extension Macro editing is identical to
editing macros 1 through 8, please refer to section 6.5.1 for more details.