CYP CR-CS4 handleiding
Handleiding
Je bekijkt pagina 16 van 36

11
Set Destination: Clicking on the edit icon ( ) allows you to edit
the post-execution delay value as well as set the interface and all
associated settings for that command.
- Delay(ms): This setting is the length of time to wait before
sending the next command and is set in milliseconds.
- Interface: The interface for sending commands can be set to
the unit itself (SysCMD), to a specied IP address (TELNET), to a
specied serial port (COM), to a specied IR port (IR) or to trigger
a relay port (Relay). Sending commands to devices on the local
network, or across the internet requires entering the IP address
and network port of the destination device. Once the destination
information is complete please click on the “Save Change” button.
Note: It is strongly suggested to not set a delay time less than 100ms
for system, serial, IR, and relay commands or less than 500ms for
Telnet commands to ensure that the command is properly received
and executed before the next command is sent.
Delete Command: Clicking on the delete command icon (
) will
remove the associated command from the execution list.
Execution Condition: Use the dropdowns to set a specic
condition for each step in the macro to execute or not. If an
execution condition tests as “false” when it is time to execute that
command, then that step of the macro will be skipped. Selecting
“None” means the macro command will always be executed.