22Curtis Instruments enGage
®
VI Manual
EMC Specications continued
Immunity
Designed to meet the following:
Radiated Immunity: ISO 11451-1, 30V/m with 80% amplitude modulation (AM)
with a 1 kHz sinusoid, ISO 11452-4 Bulk Current Injection.
Conducted Immunity: ISO 7637-2.
ESD Immunity: ISO 10605 ±15kV air discharge and ±8kV contact discharge.
Compliance
RoHS 2: enGage VI and enGage VII.
4.0 TROUBLE-SHOOTING
GENERAL
Problem / Possible Cause
No Display –
V+ (keyswitch) voltage not present at J1–1, J1-3.
Battery voltage too low. Battery terminals not connected.
Display Too Dark/Light –
LCD backlight not adjusted correctly.
BDI FUNCTION
Problem / Possible Cause
No Display –
Terminals not connected.
Improper voltage – Check B+ / B- is connected to proper pins (see tables earlier in this manual).
Stays At FULL –
Instrument voltage range selected does not match battery voltage.
V+ connected to wrong terminal.
BDI information coming from CAN network, CAN network value not correct.
Will Not Reset –
Instrument voltage does not match battery voltage.
Battery not fully charged, battery may be defective.
BDI information coming from CAN network, CAN network value not correct.