Resets Without Charging Battery –
Not connected directly to battery terminals.
Empty Too Soon –
Range Select V+ connected to wrong terminal.
Instrument voltage does not match battery voltage.
Terminals not connected directly to battery.
REAL TIME CLOCK (RTC)
Problem / Possible Cause
Correct Time, Date Not Saved When Main System Power (Battery) Disconnected –
Internal battery depleted. Note that internal RTC battery life rated for 10 years minimum.
Correct Time, Date Not Shown On Main Display –
Time, date not set correctly per RTC time, date set section of manual.
SENDER FUNCTION
Problem / Possible Cause
No Display –
Improper voltage – Check B+ / B- is connected to proper pins (see tables earlier in this manual)
Stays At Maximum/Minimum –
Sender or sender connection issues.
Sender connected to wrong terminal.
Incorrect sender used.
MAINTENANCE FUNCTION
Problem / Possible Cause
Will Not Reset –
Procedure as described in earlier section not being followed.