21Curtis Instruments enGage
®
VI Manual
3.0 ENVIRONMENTAL SPECIFICATIONS
Temperature
Operating:
–40°C to +70°C
(see *Note below)
Storage:
–40°C to +85°C
Cycling:
Per SAE J1455 section 4.1.3.1.
Shock:
Per SAE J1455 section 4.1.3.2.
*Note: Deviation from SAE J1455 Aug. 95, section 5.2.1.1 maximum temperature of +85°C due to LCD module limitations.
Humidity
Applicable to enclosed units only: 95% RH (non-condensing) at +38°C as per
SAE J1455 Aug. 94, section 4.2.3.
Water / Dust Ingress, IP Rating
Applicable to enclosed units only: sealed front and rear to IP67 with video connector (J5) installed.
Lens Fogging
Applicable to enclosed units only: meets SAE 1810, section 5.6.1.
Lens Scratch Resistance
The standard glass lens is chemically strengthened. The optional polycarbonate lens is hard coated
on the outside.
Salt Spray (Fog)
Applicable to enclosed units only: meets SAE 1810, section 5.7.1.1.
Shock
Applicable to enclosed units only: meets SAE 1378 July 98, section 5.6.
Vibration
Applicable to enclosed units only: Meets SAE J 1378 July 98, section 5.5.
EMC Specications
Emissions
Designed to meet the following:
Radiated Emissions: Broadband and Narrowband: UN ECE/324 Addendum 9 Regulation 10
Revision 4 for an Electrical/electronic sub-assembly (ESA).