Curtis 700 handleiding
Handleiding
Je bekijkt pagina 19 van 23

17
703 Counter continued
The input signal must be applied for 1/2 second
minimum (AC/DC model) or for 1 millisecond
minimum (DC Only model). If power (pins 1 & 2) has been
applied for 5 seconds minimum, the incremented count
will be stored in non-volatile memory when power is
removed.
To Reset: (for resettable models) Apply DC+ or AC hot to
pin 4 for 1/2 second minimum while power (pins 1 & 2) is
applied for 5 seconds minimum. The reset voltage must
be at the same level as the voltage used to power the unit.
732 Hour Meter (DC Only)
To Activate Display: Apply DC+ to pin 1 and DC- to pin 2.
To Activate LED: Apply DC+ (for active-high models) or
DC- (for active-low models) to pin 3 during indicator-on
condition.
To Activate Elapsed Time: For models without separate
enable option - elapsed time is activated when power is
applied to pins 1 & 2. For models with enable option -
apply signal to pin 4. Note: Power (to pins 1 & 2) must be
applied before or at the same time as signal to pin 4.
Bekijk gratis de handleiding van Curtis 700, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Curtis |
Model | 700 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 1078 MB |