18
732 Hour Meter continued
Operation: Apply DC+ to pin 4 for 1 millisecond
minimum. Activation (accumulation) of elapsed
time is indicated by the hourglass icon flashing. Time
accumulated will be stored into non-volatile memory when
power is removed, if power (to pins 1 & 2) has been applied
for the minimum of 5 seconds.
Reset: (for resettable models), Apply DC+ to pin 4 for 1/2
second minimum, while power to pins 1 & 2 has been
applied for 5 seconds minimum. Note: The reset voltage
must be at the same level as the voltage used to power
the unit.