5 — SDO COMMUNICATIONS
Curtis 1352 eXm Manual, June 2021
Return to TOC
pg. 22
TABLE 2 COLUMN DEFINITIONS
Access: RO = Read Only access; RW = Read/Write access
Index: e CAN address that is used to access this parameter.
Sub-index: Some parameters have several values associated with them. In these cases, a Sub-index
is used to access each part of the parameter.
Range, CAN Value, and Resolution:
e Range is the natural value (volts, amps, hours) that we think of when adjusting the
settings. Settings will be in tenths, hundredths, or thousandths, as applicable. Examples:
10.3 volts = 103 (in tenths of a volt)
2.01 amps = 201 (in hundredths of an amp)
10.5% = 105 (in tenths of a percent)
0.025 sec = 25 (in milliseconds, thousandths of a second)
65000 hrs = 65000 (no scaling on time)
e CAN Value is the actual value that must be written or is read over the CAN bus.
e CAN Value is stated on the second line (in italics) and provides the equivalent data
value that must be sent to archive the setting desired. For example, to set the Heartbeat
Rate to 1 second, a value of 1000 must be sent.
e Resolution (if present) provides the step-size for the CAN values. For example,
the Heartbeat Rate cannot be set to 1.003 seconds (CAN value of 1003) because it has
a resolution of 4. If a Heartbeat Rate of 803 is sent to the eXm, the eXm will truncate
and write the value 800 internally and respond with an SDO Acknowledge of 800 (the
value written with a even step size of 4).