5 — SDO COMMUNICATIONS
pg. 23
Return to TOC Curtis 1352 eXm Manual, June 2021
TABLE 2 PARAMETER DEFINITIONS
Manufacturer’s Status Register, Store Parameters, and Restore Parameters require further explanation.
Manufacturer’s Status Register
e Manufacturers Status Register reects the present fault ags. Each fault has its own bit in the
Status Register. Unlike the LED Status of the Emergency Message, which can only relay the highest
priority fault, the 32-bit Status Register shows all present faults.
Fault Bit Location Description*
Internal_Fault LSB: Bit 0 Internal hardware or Software fault
EEPROM_Fault Bit 1 EEPROM did not write, or checksum failure
Over_Voltage Bit 2 Supply is over the set voltage limit
Under_Voltage Bit 3 Supply is under the set voltage limit
Over_Temperature Bit 4 Temperature is over the 95°C limit
Under_Temperature Bit 5 Temperature is under the –50°C limit
Driver_Current_Limit Bits 6 – 11 Driver 1 6 is over the current limit
Driver_Open_Detect Bits 12 – 17 Driver 1 6 output pin is disconnected
PDO_Timeout Bit 18 Too much time between PDOs
SDO_Fault Bit 19 SDO was aborted
CAN_Bus Bit 20 CAN Bus error frame faults
Bits 21 – 31 Reserved (presently unused)