Curtis 1229 handleiding

143 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 36 van 143
3 — I/O MAPPING
1229 Manual - OS 1.8 RevA - May 2021
Return to TOC
pg. 30
Example 2: Using pot inputs for switches
is example illustrates using the pot inputs as switches. Reference Figure 7, which employs a SPDT
switch connected to Pots 2 & 3 for use as a redundant Emergency Reverse input.
12-Pot 2
Max = 4.0 V
Min = 1.0 V
Fault High = 4.5 V
Fault Low = 0.5 V
Fault Action = 1
Signal #12
Signal #13
Signal #14
Signal #15
Signal #18
Signal #19
14-Threshold 1
Input = 12 (Pot 2)
On Threshold = 50%
Off Threshold = 25%
18-Debounce 1
Input = 14 (Threshold)
On Threshold = 50%
Off Threshold = 25%
13-Pot 3
Max = 4.0 V
Min = 1.0 V
Fault High = 4.5 V
Fault Low = 0.5 V
Fault Action = 0
15-Threshold 2
Input = 13 (Pot 3)
On Threshold = 50%
Off Threshold = 25%
19-Debounce 2
Input = 14 (Threshold)
On Threshold = 50%
Off Threshold = 25%
98-Emergency Rev
Input N/O = 18 (Debounce 1)
Input N/C = 19 (Debounce 2)
Fwd Only = On
Max Current = 100%
Dir Interlock = On
Time Limit = 0.5 s
Speed = 15%
Accel = 1.0 s
Decel = 1.0 s
Use the reshold functions to convert analog signals (0–100%) to digital (on/o). is is how to
use the use the pot inputs as programmable switches. e Debounce functions lter the threshold
before completing the mapping to the Emergency Reverse function.

Bekijk gratis de handleiding van Curtis 1229, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCurtis
Model1229
CategorieNiet gecategoriseerd
TaalNederlands
Grootte19864 MB