3 — PROGRAMMABLE PARAMETERS
pg. 49
Return to TOC Curtis Model 1226BL – July 2024
DIGITAL/ANALOG INPUTS MENU
e Digital/Analog Inputs menu lets you enable and congure the analog/digital inputs (pins J3-4
and J3-6). e menu consists of the Digital/Analog Input 1 and Digital/Analog Input 2 menus, which
are described in the following topics.
Digital/Analog Input 1 Menu
e following table describes the Digital/Analog Input 1 parameters.
Note: To monitor the analog input voltage and the digital switch state, use the Inputs menu.
DIGITAL/ANALOG INPUTS MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Type
[PCF]
0x332D01
0–3
0
0–3
16-bit
Species how the input will be used:
0 = Disable
1 = Lower Valve Input
2 = Lift Inhibit High Active
3 = Lift Inhibit Low Active
4 = Lift Lockout
If the value is 1 but the External Status LED Enable parameter
is on, a Parameter Mismatch fault will occur.
Digital Input Low Threshold
0x332F01
0.00–19.00V
3.00V
0–1900
16-bit
Species the analog input voltage below which the digital
switch state changes to off (low).
Digital Input High Threshold
0x333001
0.00–19.00V
5.00V
0–1900
16-bit
Species the analog input voltage above which the digital
switch state changes to on (high).
Digital/Analog Input 2 Menu
e following table describes the Digital/Analog Input 2 parameters.
Note: To monitor the analog input voltage and the digital switch state, use the Inputs menu.
DIGITAL/ANALOG INPUTS MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Type
[PCF]
0x333101
0–3
0
0–3
16-bit
Species how the input will be used:
0 = Disable
1 = Lower Valve Input
2 = Lift Inhibit High Active
3 = Lift Inhibit Low Active
4 = Lift Lockout
The value can conict with other parameter values and cause
a Parameter Mismatch fault. The following list describes
these conicts:
• The value is non-zero but the EMR Input Type parameter
indicates an NC switch is used.
• The value is 1 but the External Status LED Enable
parameter is on.
Digital Input Low Threshold
0x333301
0.00–19.00V
3.00V
0–1900
16-bit
Species the analog input voltage below which the digital
switch state changes to off (low).
Digital Input High Threshold
0x333401
0.00–19.00V
5.00V
0–1900
16-bit
Species the analog input voltage above which the digital
switch state changes to on (high).