3 — PROGRAMMABLE PARAMETERS
Curtis Model 1226BL – July 2024 Return to TOC
pg. 48
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
EMR SRO Type
0x335E01
Enumerated
SRO on Interlock &
Throttle
0–2
16-bit
Species the type of checks the controller performs for the
EMR SRO fault.
0 = SRO Off
1 = SRO on Interlock
2 = SRO on Interlock & Throttle
Note: The controller checks for fault type 1 of the EMR SRO
fault regardless of which value is specied.
EMR Interlock
0x349401
Off/On
On
0–1
8-bit
Species whether the interlock must be cleared before the
operator resumes driving after an emergency reverse operation:
On = The interlock, direction switches, and throttle must
be cleared.
Off = Only the direction switches and throttle must be cleared.
EMR Time Limit
0x349701
0–30s
5s
0–3750
16-bit
Indicates how long emergency reverse will be active after the
vehicle starts moving in reverse.
EMR Speed
0x349601
10%–100%
60%
3276–32767
16-bit
Species the maximum vehicle speed during emergency
reverse. The value is a percentage of the maximum speed.
EMR Accel Rate
0x349201
0.1–8.0s
0.8s
50–4000
16-bit
Species the rate at which the vehicle accelerates in the
opposite direction after emergency reverse stops the vehicle.
EMR Decel Rate
0x349301
0.1–8.0s
0.8s
50–4000
16-bit
Species the rate at which the vehicle brakes to a stop when
emergency reverse is activated.
EMERGENCY REVERSE MENU, cont’d