3 — PROGRAMMABLE PARAMETERS
pg. 47
Return to TOC Curtis Model 1226BL – July 2024
EMERGENCY REVERSE MENU
Use the parameters in the following table to congure the emergency reverse feature.
EMERGENCY REVERSE MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
EMR Input Type
[PCF]
0x349801
0–2
0
0–2
16-bit
Species whether emergency reverse is activated from the
normally open (NO) switch, normally closed (NC) switch, or a
complementary usage of both NO and NC switches:
0 = NO switch
1 = NC switch
2 = Complementary NO and NC switches
If an NC switch is used but the Digital/Analog Input 2
menu's Type parameter is non-zero, a Parameter Mismatch
fault will occur.
EMR NO Switch Source
0x536100
Enumerated
EMR NO
0–9
8-bit
Species the source of the emergency reverse NO input:
0 = CAN Switch
1 = Interlock
2 = EMR NC
3 = Charger Inhibit
4 = EMR NO
5 = Forward
6 = Reverse
7 = Mode
8 = Lift
9 = Digital 1
EMR NC Switch Source
0x536200
Enumerated
EMR NC
0–9
8-bit
Species the source of the emergency reverse NC input:
0 = CAN Switch
1 = Interlock
2 = EMR NC
3 = Charger Inhibit
4 = EMR NO
5 = Forward
6 = Reverse
7 = Mode
8 = Lift
9 = Digital 1
BB Check Enable
0x535F00
Off/On
Off
0–1
8-bit
Species whether the belly button check function is enabled.
EMR Fwd Only
0x349501
Off/On
On
0–1
8-bit
Species whether emergency reverse can be activated when
driving in either direction:
On = Activated only when driving forward.
Off = Activated when driving in either direction.