Low BDI Menu
e Low BDI menu contains the following parameters.
LOW BDI MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Low BDI Max Speed
0x32CA00
0–100%
100%
0–8192
16-bit
Species the maximum speed when the battery state-of-charge is
below Low BDI Threshold. The value is a percentage of the active
speed mode’s maximum speed.
Low BDI Threshold
0x32C00A
0–100%
0%
0–100
8-bit
Species the battery state-of-charge below which the controller
applies the low BDI speed limit.
Overvoltage and Undervoltage Protection
e following list describes the controller's overvoltage and undervoltage protection:
• e overvoltage controller cuts back regen current to prevent damage to batteries and other
components. e User Overvoltage parameter species the overvoltage limit.
• e undervoltage controller is a closed loop PI (Proportional/Integral) controller that
cuts back drive current to keep battery voltage from drooping. Undervoltage protection
prevents systems from operating at voltages below minimum voltage requirements. e User
Undervoltage parameter species the undervoltage limit.
Note: e controller’s voltage ranges are listed in Specications.