3 — PROGRAMMABLE PARAMETERS
pg. 43
Return to TOC Curtis Model 1226BL – July 2024
BDI MENU
PARAMETER
CAN INDEX
VALUES
DEFAULT
RAW VALUES
DATA SIZE DESCRIPTION
Reset Volts Per Cell
0x33A701
0.900–3.000V
2.090V
900–3000
16-bit
Species the battery cell voltage at or above which the
controller resets the BDI percentage to 100% if both of the
following conditions are true when the vehicle is powered up:
Keyswitch Voltage > (Reset Volts Per Cell * the number
of cells)
BDI percentage < BDI Reset Percent
Specify a voltage that is higher than the Full Volts Per Cell voltage.
Full Volts Per Cell
0x33A401
0.900–3.000V
2.040V
900–3000
16-bit
Species the battery cell voltage at or above which the battery
is considered 100% charged. When the battery voltage drops
below this voltage, the battery begins to lose charge.
Empty Volts Per Cell
0x33A301
0.900–3.000V
1.730V
900–3000
16-bit
Species the battery cell voltage at which the battery cell is
considered 0% charged.
Discharge Time
0x33A201
0–600 minutes
600 minutes
0–600
16-bit
Species the minimum time for decrementing the BDI
percentage from 100% to 0% if the battery cell voltage is lower
than the Empty Volts Per Cell voltage.
BDI Reset Percent
0x33A601
0%–100%
75%
0–100
16-bit
Species the percentage of battery voltage above which the
BDI percentage will not reset when the keyswitch is turned on.
When a battery has a high BDI percentage, its oat voltage
when the keyswitch is powered on could cause false BDI
resets. The BDI Reset Percent parameter lets you preempt this
problem by specifying a minimum threshold for resetting the
BDI percentage.
Full Charge Voltage
0x339B01
0.900–3.000V
2.350V
900–3000
16-bit
Species the voltage above which the controller considers the
battery as nished charging.
Start Charge Voltage
0x339C01
0.900–3.000V
2.100V
900–3000
16-bit
Species the voltage above which the controller considers the
battery as starting to charge.
Charge Time
0x339D01
0–600 minutes
300 minutes
0–600
16-bit
Species how many minutes it takes for the BDI percentage to
increase from 0% to 100% while the battery is being charged.
When a charger is plugged in, the battery voltage gradually
increases to the full level. To accurately reect the state-of-
charge, during charging the BDI percentage increases by 1%
when the specied number of minutes elapses.
Note: Higher battery amp/hour ratings require a larger
Charge Time.
Note: Some parameters congure the controller’s overvoltage and undervoltage protection, which
is described in Overvoltage and Undervoltage Protection.
e controller can apply a speed limit when the battery’s state-of-charge is low. e parameters on
the Low BDI menu congure the speed limit.