3 — PROGRAMMABLE PARAMETERS
Curtis Model 1220E – August 2022 Return to TOC
pg. 16
0 - COMMAND ANALOG 1 AND 2
NAME
ALLOWABLE
RANGE RAW DATA DESCRIPTION
Command Analog1 Left
(0x333000, 16bits)
0 – 5.50V
0 – 3605
Denes the command analog1 wiper voltage required to produce a steer
position command of full left.
(Steer Command = –100% = Left Stop)
Command Analog1 Center
(0x333100, 16bits)
0 – 5.50V
0 – 3605
Denes the command analog1 wiper voltage required to produce a steer
position command of center.
(Steer Command = 0% = 0°)
Command Analog1 Right
(0x333200, 16bits)
0 – 5.50V
0 – 3605
Denes the command analog1 wiper voltage required to produce a steer
position command of full right.
(Steer Command = 100% = Right Stop)
Command Analog1 Fault Min
(0x333300, 16bits)
0 – 5.50V
0 – 3605
Sets the minimum threshold for analog1 pot input. If command wiper
voltage goes below this threshold for 60 msec, a fault is issued.
Command Analog1 Fault Max
(0x333400, 16bits)
0 – 5.50V
0 – 3605
Sets the maximum threshold for analog1 pot input. If command wiper
voltage rises above this threshold for 60 msec, a fault is issued.
Command Analog2 Left
(0x333500, 16bits)
0 – 5.50V
0 – 3605
Denes the command analog2 wiper voltage required to produce a steer
position command of full left.
(Steer Command = –100% = Left Stop)
Command Analog2 Center
(0x333600, 16bits)
0 – 5.50V
0 – 3605
Denes the command analog2 wiper voltage required to produce a steer
position command of center.
(Steer Command = 0% = 0°)
Command Analog2 Right
(0x333700, 16bits)
0 – 5.50V
0 – 3605
Denes the command analog2 wiper voltage required to produce a steer
position command of full right.
(Steer Command = 100% = Right Stop)
Command Analog2 Fault Min
(0x333800, 16bits)
0 – 5.50V
0 – 3605
Sets the minimum threshold for analog2 pot input. If command wiper
voltage goes below this threshold for 60 msec, a fault is issued.
Command Analog2 Fault Max
(0x333900, 16bits)
0 – 5.50V
0 – 3605
Sets the maximum threshold for analog2 pot input. If command wiper
voltage rises above this threshold for 60 msec, a fault is issued.
Analog Input Signal Flow Diagram
Command Analog 1
(Pin J3-6)
[5.0V]
[12 bits]
Command Analog Left
Command Analog Center
Command Analog Right
Steer Command
NormalizationLow Pass FilterAnalog/Digital ConverterDivider + Filter
+100%
0
−100%
Figure 4
Command signal ow
e normalization map takes Analog 1 in volts and maps it to Steer Command in percent. Command
Analog Le may be set higher or lower than Command Analog Right. Command Analog Center
must be between Command Analog Le and Command Analog Right. If Command Analog Le

Bekijk gratis de handleiding van Curtis 1220E, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.