Continental 1RE-N-HD handleiding

44 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 16 van 44
16
REACH-INS & ROLL-INS
OPERATIONS MANUAL
TOP-MOUNT PLUG BOX REFRIGERATION SYSTEM
Evaporator Housing on Top of Cabinet
The plug-type evaporator system is a unique system in which
the evaporator coil and air circulating fans are contained within
a concealed plug-type insulated housing, readily accessible on
the top of the cabinet and separate from the food storage zone
(see Figure 9A & 9B). The entire plug system is fully charged
with refrigerant and mounted on a steel rail type base which can
be easily removed from the cabinet for locations with restricted
access for installations, or if a field conversion (refrigerator to
freezer or vice versa) is desired. Before attempting to remove
plug assembly, consult factory.
FIGURE 9B: Roll-In Refrigeration System
A
DETAIL A
SCALE 1 : 10
REFRIGERATION SYSTEM
ROLL-IN
EVAP. HOUSING
EVAPORATOR COIL
FAN PANEL
SIDE
AIR DUCTS
AIR BAFFLE
BAFFLE
CONNECTORS
TEMP. CONTROL
THERMAL LIMIT
CONDENSER
(INTERIOR TOP)
COMPRESSER
DRAIN PAN
LID
DEFROST HEATER
(IN HOUSING)
(FREEZER ONLY)
CONTROL BOX
(FREEZER ONLY)
POWER CORD
LID SCREWS
DEFROST TIMER
FIGURE 9A: Top-Mount Evaporator Housing Refrig. System
D
DETAIL D
SCALE 1 : 10
LID SCREWS
LID
EVAPORATOR COIL
EVAPORATOR
HOUSING
FAN PANEL
DRAIN PAN
DEFROST
HEATER
AIR DIVIDERS
COMPRESSOR
CONDENSER
THERMAL LIMIT
CONTROL BOX
AIR BAFFLE
TEMP. CONTROL
POWER CORD
DEFROST
TIMER
REFRIGERATION SYSTEM
DESIGNER LINE
(INTERIOR TOP)
(IN HOUSING)
(FREEZER ONLY)
(FREEZER ONLY)
FIGURE 9: Ceiling-Mount Evaporator Refrigeration System
A
DETAIL A
SCALE 1 : 8
VALUE LINE COIL HOUSING PARTS
DEFROST
HEATER
FAN GUARD
HOUSING
END
COIL COVER
/ DRAIN PAN
FAN MOTOR
ASSEMBLY
EVAPORATOR
COIL
COMPRESSOR
CONTROL
BOX
MODULAR
PLUG
THERMAL LIMIT SWITCH
TEMPERATURE
CONTROL
CONDENSER
(FREEZER ONLY)
(FREEZER ONLY)
DEFROST
TIMER
Warming cabinets are not designed to cook food. All foods
placed in the warming cabinet should be precooked and at, or
above the desired holding temperature. Never place cold or
uncooked foods in the cabinet. It is recommended that hot
foods be kept above 140°F to retard bacterial growth. Foods that
are steaming should always be covered.
IMPORTANT NOTE: The operating range of the warmer
temperature control is is 60°F to 180°F. Never allow
the cabinet temperature to exceed 200°F since serious
damage could result to your warming cabinet and the
warranty will become null and void.
STANDARD REACH-IN REFRIGERATION SYSTEM
Ceiling-Mount Evaporator
The low-profile evaporator system is comprised of a gener-
ous sized, evenly matched evaporator and air circulating fans
contained within an easily accessible, low silhouette, interior
ceiling mounted housing (see Figure 9). A control box, located
on top of the cabinet, contains the temperature control, thermal
limit switch, defrost time clock (for freezers) and other electrical
components.
All standard reach-in refrigerators and freezers built after June,
2009 have a unique, modular refrigeration system. The com-
plete, fully charged refrigeration unit can be easily removed from
the cabinet for locations with restricted access for installation,
servicing, conversion from a refrigerator to freezer (or vice
versa) or other needs. Contact the service department for more
information.