THESE INSTRUCTIONS ARE FOR USE WITH DISSOLVE
®
DESCALER SOLUTION Cleveland Range
Part Nos. 106174 or 1061741 ONLY.
•
Health Hazard Data, Effects of Overexposure – This product may cause a burning sensation to eyes
or skin.
•
Emergency and First Aid Procedures - In case of eye contact, immediately flush eyes with plenty of
water. If irritation persists seek medical attention. In case of skin contact, wash with soap and water. If
inhaled, remove to fresh air and if burning persists, call a physician. If swallowed, drink 1 or 2 glasses of
water and call a physician.
•
Spill or Leak Procedures – Rinse with plenty of water to dilute. Sodium carbonate or calcium
carbonate may be used to soak up liquid. Considered non-hazardous, spent material may be disposed
of in a sewer system with water flush.
a. MODEL 24CGA6.2S, 24CGA6.2SES, 24CGA10.2 ,and 24CGA10.2ES, ATMOSPHERIC
STEAM GENERATOR DESCALING PROCEDURE (For DISSOLVE
®
Descaler Solution Part No.
106174 or 1061741)
Monthly Intervals
1. This procedure will take approximately 1 hour and 30 minutes to complete.
2. Set both timers to zero or for manual only models, set both compartment ON/OFF selector
switches to OFF.
CAUTION
Do not use any other product or method of descaling other than the
DISSOLVE
®
Descaler method using Part Nos. 106174 or 1061741.
WARNING
The liquid solution in Cleveland Range Descaler Solution Part No. 106174 or 1061741
can be harmful if not handled properly. Follow these basic safety rules for handling and
using this product.
Wear protective clothing when mixing or applying chemical cleaners.
Wear rubber gloves, and OSHA approved eye protection when descaling to avoid
personal injury.
Avoid breathing fumes. If liquid comes in contact with skin, wash with soap and water.
If chemical contacts eyes, flush with water. If irritation persists seek medical attention
If chemical is swallowed or ingested, drink 1 or 2 glasses of water and call a physician.
WARNING
This procedure is slightly different depending on the model being
descaled. This entire procedure should be read and fully
understand as it applies to the model being descaled, before
beginning the actual descaling operation.