3. Open both doors to the cooking compartments.
4. Set the TIMED/MANUAL switches to TIMED.
5. Set both ON/OFF levers/switches to the OFF position. (The unit will undergo a normal
blowdown cycle, which should take approximately 3 minutes to complete).
6. Remove both caps from the descale ports located at the top of the unit (See Figure 6-1),
7. When the unit has completed draining, set both ON/OFF levers/switches to ON, this will refill
the generators. Do not start the timer and leave the cooking compartment doors open.
Monthly Maintenance (continued)
NOTE: DO NOT HEAT THE UNIT DURING DESCALING.
8. While the unit is filling with water add 1 gallon of
DISSOLVE
®
descaler solution into each descaling port.
While adding liquid to the unit through the descaler
inlets, pour it in slowly so as to avoid overflow.
9. After the automatic fill cycle has ended, turn OFF power
at the external main power switch. See Figure 6-2. DO
NOT change the position of the ON/OFF levers.
(FOR THE MODELS 24CGA10.2 and 24CGA10.2ES
ONLY add cold tap water through one descale port until
water enters the cooking compartment through the
steam nozzles or until the descaling port overflows
(water required varies between 1 to 2 gallons depending
on the Model). Repeat with the second descale port.)
10. At the end of 1 hour, set the ON/OFF levers/switches to
the OFF position, which will drain the generators (takes
about 3 minutes).
11. Restore power to the unit by turning the power back ON
at the external main power switch.
12. Set both ON/OFF levers to ON to refill generator. When
full, add ½ to 1 gallon ( 1 to Gallons for the Model
24CGA10.2) of water through each descale port (to
remove foam from the water level controls)
13. Set both ON/OFF levers to OFF to drain the generators.
14. After the unit has drained completely, close the steamer
doors and set the ON/OFF levers/switches to the ON
position. The unit will fill with water.
15. Set the timers for 20-30 minutes, and turn them on
(KEYPAD MODELS). The unit will come up to normal
operating temperature.
16. At the end of 20-30 minutes of cooking, turn OFF the alarm (if necessary) and set the ON/OFF
levers/switches to the OFF position to drain the generators. Wait at least 5 minutes to ensure
complete draining.
17. This is the final blowdown to rinse the unit. The steamer is now ready for normal operation.
18. When done cleaning, reset the descale indicator light timer to zero by pressing the “DESCALE
REQUIRED” lighted rocker switches, and resume normal operation.
Figure 6-1 Descaling Port
Gemini
DRAIN LINE
COLD WATER SUPPLY LINES
MAIN EXTERNAL
POWER SWITCH
Figure 6-2 Main External
Power Switch