problems do occur, refer to the Troubleshooting Guide in this chapter. For more information on products and
services, contact your sales representative.
1. Maintenance Records
Make a file solely for maintenance records. Keep a written record of daily, weekly, monthly, and yearly
maintenance. These records will protect warranty coverage, help personnel to know when to perform
various maintenance procedures, and assist service personnel.
2. Daily Maintenance
a. Blowdown Steam Generator
Blowdown each steam generator according to the steam generator blowdown instructions in
Chapter 6.
b. Clean the Steamer
Clean interior and exterior of the steamer according to the shutdown instructions in Chapter 6.
3. Weekly Maintenance
Clean Drain
This steamer is equipped with a drain screen in the back of each cooking compartment. Never operate the
steamer without the screens in place. The screen prevents large food particles from entering and blocking
the drain line. Any blockage of the drain line can cause a pressure buildup in the compartment, resulting in
steam leaks around the door gasket. Drain line blockage also adversely affects convection action of the
steam in the compartment, which is necessary for optimum performance.
a. Inspect the drain screen and drain line for blockage. Rotate the drain screen 90 degrees to
inspect the drain opening. Clean the opening and restore the screen to its operating position.
b. Clean drain with a USDA approved drain cleaner, once a week. Follow the instructions of the
manufacturer of the cleaner.
c. Flush drain with clean water.
4. Monthly Maintenance
Descale Steam Generator
Steam generators should be descaled at least once a month, depending on scale buildup. If you have
serious steam generator scale buildup, a water treatment system should be installed for the steamer or if
this is not possible the frequency of descaling should be increased. This unit is equipped with a Descaling
reminder light to assist in the scheduling of this maintenance. (Note: the descaling light has been factory set
for an operating time of approximately 1 month, if a different descaling frequency is required it will be
necessary to have the descaling timer reset to reflect this schedule by a qualified service technician). When
this light comes on arrangements should be made to descale the steam generator as soon as feasible.
Cleveland Range, recommends the use of DISSOLVE
®
Descaler Solution, Cleveland Range Part No.
106174. No other system of steamer descaling should be used.
NOTE: Part No. 106174 is the Part No. for a case (6 1-gallon containers) of DISSOLVE
®
descaler. It is also
available in 5-gallon containers as Part No. 1061741.
CAUTION
Steam leaks, pressure buildup in the cooking compartment and poor
steaming performance can be caused by a blocked drain line or screen.
Blocked or slow drains are dangerous because hot water can collect in the
compartment and spill out when opening the compartment door.