Optional Weekly Cleaning Intervals
1. Follow same process as above, except add one quart of DISSOLVE
®
descaler (Part No. 106174)
instead of one gallon of DISSOLVE
®
descaler to each generator.
B. OPERATORS TROUBLESHOOTING GUIDE
The Troubleshooting guide includes a list of symptoms that may be encountered during routine operation
and maintenance. The first column on the left (PROBLEM) describes these symptoms. The second column
lists the possible causes for the problem in column one. The third column lists possible remedies for the
problems and causes in columns one and two. The causes and remedies are listed in the order they should
be checked, with the least costly and easiest to repair listed first. The third column also refers to notes that
are grouped at the end of the troubleshooting guide. Refer to these notes when instructed to do so.
Table 6-1 Troubleshooting Guide
PROBLEM POSSIBLE CAUSE REMEDY/REFERENCE
Power turned OFF at main external
power switch.
Turn ON power at main external power
switch.
ON/OFF lever/switch not fully
turned to the ON position.
Turn lever/switch to the full ON position.
Power indicator light does
not turn ON when
ON/OFF lever/switch is in
the ON position.
Inoperative controls or failed light. See note #1
Water supply to steamer shut OFF. Open water supply valves.
Water line strainer and/or external
filter system is clogged
Clean water supply strainer and/or filter
system.
Power ON and steam
generator does not fill.
Inoperative Solenoids or controls. See note # 1.
Water supply to steamer shut OFF. Open water supply valves.
Gas Supply turned OFF Turn ON gas supply
Door interlock switch not engaged
or has failed.
Close door completely. If problem
persists see note #1.
Water line strainer and/or external
filter system is clogged
Clean water supply strainer and/or filter
system.
Hi-limit switch has tripped. See note #1.
Control panel POWER
indicator light ON and
steamer does not make
any steam in MANUAL or
TIMED mode.
Inoperative controls or solenoid. See note #1.
Water supply to condenser turned
OFF.
Open water supply valve.
Hot water instead of cold water
connected to condenser fitting.
See note #2.
Condenser water line strainer is
clogged.
Clean out condenser water supply
strainer. See note #1.
Condenser is clogged. See note #1
Water supply line to the condenser
blocked, broken, or leaking.
Repair or replace water supply line. See
note #3.
Abnormal amount of
steam coming from drain.
Inoperative controls or solenoids.
Turn OFF electricity at main external
power switch. See note #1.
Abnormal amount of
steam coming from drain
during blowdown cycle.
ON/OFF lever/switch is not turned
fully to the OFF position.
Turn ON/OFF lever/switch to the full
OFF position to start the proper
blowdown operation.
(Continued on next page)