18
Monthly/Weekly Maintenance (continued)
a. MODEL 24CGA6.2 and 24CGA10.2, ATMOSPHERIC STEAM GENERATOR DESCALING
PROCEDURE (For DISSOLVE
®
Descaler Solution Part No. 106174 or 1061741)
Monthly Intervals
1. This procedure will take approximately 1 hour and 30 minutes to complete. This entire
procedure should be read and fully understood before beginning the actual descaling
operation.
2. Zero the timers or, for manual only models, set the selector switch to OFF.
3. Open both doors to the cooking compartments.
4. Set the TIMED/MANUAL switches to TIMED.
5. Set the ON/OFF levers/switches to the OFF position.
(The unit will undergo a normal blowdown cycle, which
should take approximately 3 minutes to complete).
6. When the unit has completed draining, turn the ON/OFF
levers/switches to ON to refill the unit. Do not start the
timer. Leave the doors open.
NOTE: DO NOT HEAT THE UNIT DURING DESCALING.
7. While the unit is filling with water, remove the descaling
port caps located at the top of the unit (See Figure 6-1),
and add 1 gallon of DISSOLVE
®
descaler solution to
each port.
·
While adding liquid to the unit through the descaler
inlets, pour it in slowly so as to avoid overflow.
8. After automatic fill has ended, turn OFF power at the
external main power switch. See Figure 6-2. Add an
additional 1-gallon of water to each port.
9. Replace the caps and let the unit stand for 1 hour.
10. At the end of 1 hour, set the ON/OFF levers/switches to
the OFF position and turn the power ON at the external
main power switch. After the 3-minute drain cycle,
completes turn the unit back ON. After the filling has
stopped, add 1½ gallons of water through each descale
port, and then turn the unit OFF. This will start a
blowdown cycle and drain any residue from the water
level control assembly.
11. After the unit has drained completely, close the steamer
doors and set the ON/OFF levers/switches to the ON
position. The unit will fill with water.
12. Set the timers for 20 minutes, and turn them on (KEYPAD MODELS). The unit will come up to
normal operating temperature.
13. At the end of 20 minutes of cooking, turn off the alarm (if necessary) and set the ON/OFF
levers/switches to the OFF position. The unit will go through a 3-minute drain cycle.
14. This is the final blowdown to rinse the unit. The steamer is now ready for normal operation.
15. When done cleaning, reset the descale indicator light timer to zero by pressing the “DESCALE
REQUIRED” lighted rocker switches, and resume normal operation.
Figure 6-1 Descaling Port
Gemini
DRAIN LINE
COLD WATER SUPPLY LINES
MAIN POWER SWITCH
Figure 6-2 External Main
Power Switch