4. Monthly/Weekly Maintenance
Descale Steam Generator
Steam generators should be descaled at least once a month, depending on scale buildup. Alternately, they
can be descaled weekly with smaller amounts of solution, if this frequency better suits your maintenance
schedule. If you have serious steam generator scale buildup, a water treatment system should be installed
for the steamer or if this is not possible the frequency of descaling should be increased. This unit is
equipped with a Descaling reminder light to assist in the scheduling of this maintenance. (Note: the
descaling light has been factory set for an operating time of approximately 1 month, if weekly descaling has
been chosen it will be necessary to have the descaling timer reset to reflect this schedule by a qualified
service technician). When this light comes on arrangements should be made to descale the steam
generator as soon as feasible. Cleveland Range, Inc. recommends the use of DISSOLVE
®
Descaler
Solution, Cleveland Range Part Nos. 106174. No other system of steamer descaling should be used.
NOTE: Part No. 106174 is the Part No. for a case (6 1-gallon containers) of DISSOLVE
®
descaler. It is also
available in 5-gallon containers as Part No. 1061741.
THESE INSTRUCTIONS ARE FOR USE WITH DISSOLVE
®
DESCALER SOLUTION Cleveland Range
Part Nos. 106174 or 1061741 ONLY.
·
Health Hazard Data, Effects of Overexposure – This product may cause a burning sensation to eyes
or skin.
·
Emergency and First Aid Procedures - In case of eye contact, immediately flush eyes with plenty of
water. If irritation persists seek medical attention. In case of skin contact wash with soap and water. If
inhaled, remove to fresh air and if burning persists, call a physician. If swallowed, drink 1 or 2 glasses of
water and call a physician.
·
Spill or Leak Procedures – Rinse with plenty of water to dilute. Sodium carbonate or calcium
carbonate may be used to soak up liquid. Considered non-hazardous, spent material may be disposed
of in a sewer system with water flush.
WARNING
The liquid solution in Cleveland Range Descaler Solution Part No. 106174 or 1061741
can be harmful if not handled properly. Follow these basic safety rules for handling and
using this product.
Wear protective clothing when mixing or applying chemical cleaners.
Wear rubber gloves, and splash goggles.
Avoid breathing fumes. If liquid comes in contact with skin, wash with soap and water.
If chemical contacts eyes, flush with water. If irritation persists seek medical attention
If chemical is swallowed or ingested, drink 1 or 2 glasses of water and call a physician.
CAUTION
Do not use any other product or method of descaling other than the
DISSOLVE
®
Descaler method using Part Nos. 106174 or 1061741.
Bekijk gratis de handleiding van Cleveland 24CGA10.2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Cleveland |
Model | 24CGA10.2 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3502 MB |