INSTALLATION/SETUP TRANSMIG 4RT
Manual 0-5245 3-15 INSTALLATION/SETUP
Program Number Description
Amps
A-10634
Volts
A-10635
P01
SPOT TIME, adjustable from 0.5 to 5.0 seconds
P02
BURN BACK TIME, adjustable from 0.01 to 2.00 seconds
P03
PRE FLOW TIME, adjustable from 0.01 to 9.99 seconds
P04
POST FLOW TIME, adjustable from 0.01 to 9.99 seconds
P05
MMAW (Stick) HOT START CURRENT, adjustable from 10 to 100A
P06
CREEP FEED SPEED, adjustable from 0.05 to 20 MPM
P07
Wirefeed speed units, change between IPM and MPM
P08
Displays Software revision
Table 3-1: Advanced Features
16. Fan as Needed
The TRANSMIG 350i, 450i and 550i are fitted with a
fan as needed feature. Fan as needed automatically
switches the cooling fan off when it is not required.
This has two main advantages; (1) to minimize power
consumption, and (2) to minimise the amount of
contaminants such as dust that are drawn into the
power source.
Note that the fan will only operate when required for
cooling purposes and will automatically switch off
when not required.
17. Main Three Phase Power On / Off Switch
This Three Phase circuit breaker performs a dual
function.
It is used to turn the unit on/off and it will also trip in
the event of a major fault condition.
Lift the cover for access to the circuit breaker.
!
WARNING
When the front digital displays are lit, the ma-
chine is connected to the Mains supply voltage
and the internal electrical components are at
Mains voltage potential
18. Positive Welding Terminal
Welding current flows from the Power Source via
heavy duty bayonet type terminals. It is essential,
however, that the male plug is inserted and turned
securely to achieve a sound electrical connection.
19. Negative Welding Terminal
Welding current flows from the Power Source via
heavy duty bayonet type terminals. It is essential,
however, that the male plug is inserted and turned
securely to achieve a sound electrical connection.
CAUTION
Loose welding terminal connections can cause
overheating and result in the male plug being
fused in the terminal.