Cigweld Transmig 4RT handleiding

62 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 28 van 62
TRANSMIG 4RT INSTALLATION/SETUP
INSTALLATION/SETUP 3-12 Manual 0-5245
9. Trigger Mode Control Button (MIG and LIFT TIG
Mode only) (Only applicable to 10 pin mode)
Note that this feature on the power source only applies
to devices connected to the 10 pin control socket.
In the case of wirefeeders connected to the 19 pin
socket the function is controlled from that indepen-
dant wirefeeder only.
The trigger mode control is used to switch the
functionality of the of the torch trigger between 2T
(normal),
4T (latch mode) and SPOT (spot mode)
2T Normal Mode
In this mode, the torch trigger must remain depressed
for the welding output to be active. Press and hold
the torch trigger to activate the power source (weld).
Release the torch trigger switch to cease welding.
4T Latch Mode
This mode of welding is mainly used for long weld-
ing runs to reduce operator fatigue. In this mode the
operator can press and release the torch trigger and
the output will remain active. To deactivate the power
source, the trigger switch must again be depressed
and realised, thus eliminating the need for the opera-
tor to hold the torch trigger.
Note that when operating in GTAW (LIFT TIG mode),
the power source will remain activated until the se-
lected down slope time has elapsed (refer Item 10).
SPOT Mode
This mode of welding is similar to 2T mode, except
the welding output will be active only for a preset
amount of time. This mainly used for tacking at the
start of a job setup. Press and hold the torch trigger
to activate the power source (weld). After the SPOT
time has elapsed and welding output has ceased,
release the torch trigger switch.
10. VRD ON/OFF Indicator Lights
A VRD (voltage reduction device) is a hazard
reducing device designed to reduce electric shock
hazards present on the output of welding power
source when operating in MMAW (stick) mode.
Note that the presence of VRD should not be used
as a substitute for the use of appropriate safety
practices as indicated in section one of this manual.
Both the green and red indicator lights only operate
in MMAW (stick) mode.
The green VRD ON light illuminates (red light is off)
when the VRD is active. Under this condition the
open circuit voltage of the unit is limited to below
35V DC, thus reducing the potential of serious
electric shock (such as when changing electrodes).
The red VRD OFF light illuminates (green light is
off) when the VRD is inactive. Under this condition
the output voltage of the unit will be at welding
potential which in some cases may exceed 35V DC.
The VRD incorporated within the TRANSMIG 350i,
450i and 550i is fully standards compliant to AS
60974.1 / IEC 60974-1.
11. Thermal Overload Indicator Light (Fault)
This welding power source is protected by a self re-
setting thermostat. The indicator will illuminate if the
duty cycle of the power source has been exceeded.
Should the thermal overload indicator illuminate the
output of the power source will be disabled. Once
the power source cools down this light will go OFF
and the over temperature condition will automati-
cally reset. Note that the mains power switch should
remain in the on position such that the fan continues
to operate thus allowing the unit to cool sufficiently.
Do not switch the unit off should a thermal overload
condition be present.
12. Program Storage Buttons and Display
This welding power source is able to store 10 machine
setups in memory. This memory is retained even
if mains supply power is turned off. Button status,
Amps, Volts, and Wirespeed are stored in memory
for quick change between commonly used welding
setups.
The memory will store machine setups in all three
operating modes, GMAW/FCAW (MIG), GTAW (Lift
TIG) and MMAW (Stick).
To STORE a program.
1. Press the number button. The display will change
to indicate which program number location is be-
ing used.
2. Press and Hold the SAVE button. The number on
the display will flash for 3 seconds. During this
time the current machine setup will be saved in
the numbered program location as selected.
To LOAD a program.
1. Press the NUMBER button. The display will change
to indicate which program is being used.

Bekijk gratis de handleiding van Cigweld Transmig 4RT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCigweld
ModelTransmig 4RT
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8070 MB