Cigweld Transmig 4RT handleiding

62 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 27 van 62
INSTALLATION/SETUP TRANSMIG 4RT
Manual 0-5245 3-11 INSTALLATION/SETUP
6. Local / Remote Button
The REMOTE button is used to select REMOTE or
LOCAL mode of operation.
The REMOTE button is used only when a remote
control device (such as a TIG torch with remote cur-
rent control, or a Wirefeeder) is fitted to the unit via
the remote control socket (items 5 & 6). When the
REMOTE button is in the remote position, the unit will
detect a remote device and work accordingly
When in the local mode, the unit will not detect the
remote device and will operate from the power source
controls only. Note that the trigger will operate at all
times on the remote control socket irrespective of the
position of the local remote switch (ie in both local
and remote modes).
Should a remote device be connected and the remote/
local switch set to remote, the maximum setting of
the power source will be determined by the respective
front panel control, irrespective of the remote control
device setting. As an example, if the output current
on the power source front panel is set to 50% and the
remote control device is set to 100%, the maximum
achievable output from the unit will be 50%.
Should 100% output be required, the respective front
panel control must be set to 100%, in which case the
remote device will then be able to control between
0-100% output.
7. 10 PIN / 19 PIN Remote Button
The REMOTE button is used to select 10 PIN, 19 PIN,
mode of operation when the REMOTE button ( item
13) is in REMOTE mode.
When in 10 PIN Remote mode, the 10 PIN control
socket is active and remote voltage or current / wire-
speed controls will be active.
The 10 PIN Remote mode is only available in GMAW/
FCAW (Mig) and GTAW (Lift Tig) modes only.
When in 19 PIN Remote mode, the 19 PIN control
socket is active and remote voltage controls will be
active.
The 19 PIN Remote mode is only available in GMAW/
FCAW (Mig) mode only.
NOTE
When operating a 10 pin Wirefeeder in remote
mode, the maximum output is determined
by the settings of the power source (in local
mode). This is done such that the maximum
output available at the wirefeeder can be
restricted to a preset level. This preset level
must be selected whilst the machine is in
local mode.
As an example, should 0-100% output con
-
trol be required at the wirefeeder, the power
source should be set to local mode, and both
the amps (wirespeed) and volts controls set
to 100% (maximum). the wirefeeder will then
be able to control between 0-100% of output
[both amps(wire speed) and volts].
Should 50% output be required at the
wirefeeder controls, the power source should
be set to local mode, and both the amps (wire
-
speed) and volts set to 50% (mid point). The
wirefeeder will then be able to control between
0-50% of output [both amps(wirespeed and
volts)]
NOTE
When a 19 pin wirefeeder in used, 100%
output for both amps (wirespeed) and volts is
available at the wirefeeder at all times regard
-
less of the amps (wirespeed) and volts con-
trol settings at the power source (The power
source display will show a series of dashes
when in 19 pin remote mode). The wirefeeder
can adjust both amps (wirespeed) and volts
between 0-100%.
8. Process Selection Button
The process selection control is used to select the
desired welding mode. Three modes are available,
GMAW/FCAW (MIG), GTAW (Lift TIG) and MMAW
(Stick) and Gouging (Transmig 550i only) modes.
Refer to section 3.15 or 3.16 for FCAW/GMAW (MIG)
set up details, section 3.17 for GTAW (Lift TIG) set-
up details or section 3.18 for MMAW (stick) set-up
details.
Note that when the unit is powered off the mode selec-
tion control will automatically default to MIG mode.
This is necessary so as to prevent inadvertent arcing
should an electrode holder be connected to the unit
and mistakenly be in contact with the work piece
during power up.

Bekijk gratis de handleiding van Cigweld Transmig 4RT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCigweld
ModelTransmig 4RT
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8070 MB