CAUTION
DO NOT purge oxidising or ammable gases in the
presence of ame, lit cigarettes, or other sources
of ignition or in a conned space.
Close equipment valve(s) after purging, and test all
connections for leaks with a suitable leak detection
solution or soapy water. Never use a ame when
testing for leaks.
ADJUSTING FLOW RATE
With the Regulator/Flowmeter ready for operation, adjust
working flow rate as follows:
1. Slowly turn adjusting valve in anti-clockwise direction
to open and increase until the bobbin in the ow tube
indicates the required ow rate.
NOTE
It may be necessary to re-check the shielding Gas
Regulator/Flowmeter ow rate following the rst
weld sequence due to back pressure present within
shielding gas hose assembly.
2. To reduce ow rate, allow the welding grade shielding gas
to discharge from Regulator/Flowmeter by pressing the Gas
Purge button on the front of the machine, or by pressing the
trigger on the MIG Gun. Bleed welding grade shielding gas
into a well ventilated area. Turn adjusting screw clockwise,
until the required ow rate is indicated on the gauge.
3. The correct ow rate will depend on the place and
conditions you are working in. For indoors work shielding
gas ow rate can be from 12L/min for welding thin metals
(0.6-1.0mm) when using 0.6mm MIG wire, up to 15L/min
when using thicker metals and using 0.8mm MIG wire. When
welding near draughty doorways then the gas ow rate can
go up to 18-20L/min. The tell tale sign is to ensure your
nished welds do-not have porosity holes in the surface.
Argon Regulator/Flowmeter
CylinderGas Hose
Flow Rate
Adjusting Valve
Open / Increase
Decrease / Close
Figure 5-3: Adjust Flow Rate
SHUTDOWN
Close cylinder valve whenever the Regulator/Flowmeter is
not in use. To shut down for extended periods (more than 30
minutes).
1. Close cylinder valve tightly.
2. Remove the gas from the machine and hose by pressing
the Gas Purge button on the front of the machine, or by
pressing the trigger on the MIG Gun. Bleed gas into a well
ventilated area.
3. After gas is drained completely turn off the machine.
4. Before transporting cylinders that are not secured on
a cart designed for such purposes, remove regulators/
owmeters.
WARNING
Moving Parts can cause injury!
OPERATING MANUAL BLUEVENOM 4R-ROVER
CIGWELD.COM.AU | 33