INSTALLATION
1. Remove cylinder valve plastic dust seal. Clean the cylinder
valve outlet of impurities that may clog orices and
damage seats before connecting the Regulator/Flowmeter.
Crack the valve (open then close) momentarily, pointing
the outlet away from people and sources of ignition. Wipe
with a clean lint free cloth.
2. Match Regulator/Flowmeter to cylinder. Before connecting,
check that the Regulator/Flowmeter label and cylinder
marking agree and that the Regulator/Flowmeter inlet
and cylinder outlet match. NEVER CONNECT a Regulator/
Flowmeter designed for a particular gas or gases to a
cylinder containing any other gas.
3. Connect the Regulator/Flowmeter inlet connection
to cylinder or pipeline and tighten it rmly but not
excessively, with a suitable spanner.
4. Connect and tighten the outlet hose rmly and attach
the hose to the welding machine with the Quick Connect
tting. Ensure no gas leakage. The owmeter must be in
the vertical position to read accurately.
OPERATION
With the Regulator/Flowmeter connected to cylinder or
pipeline:
1. Stand to one side of Regulator/Flowmeter and slowly open
the cylinder valve. If opened quickly, a sudden pressure
surge may damage internal Regulator/Flowmeter parts.
2. Since the regulator is a preset type, no adjustments to the
regulator are necessary. Before opening the cylinder valve,
be sure that the ow adjusting valve is in a nger-tight
“OFF” position (clockwise).
3. Slowly and carefully, open the cylinder valve until the
maximum pressure registers on the high pressure gauge.
CAUTION
Match Regulator/Flowmeter to cylinder. NEVER
CONNECT a Regulator/Flowmeter designed for a
particular gas or gases to a cylinder containing any
other gas.
2. NEVER pressurize a Regulator/Flowmeter that has loose
or damaged parts or is in a questionable condition. NEVER
loosen a connection or attempt to remove any part of
a Regulator/Flowmeter until the gas pressure has been
relieved. Under pressure, gas can dangerously propel a
loose part.
3. DO NOT remove the Regulator/Flowmeter from a cylinder
without rst closing the cylinder valve and releasing gas in
the Regulator/Flowmeter high and low pressure chambers.
4. TURN OFF When equipment is not in use for extended
periods of time, shut off the gas at the cylinder valve and
release the gas from the equipment.
5. OPEN the cylinder valve SLOWLY. Close after use.
A
rgon Regulator/Flowmeter
Gas Hose
Cylinder
Figure 5-2: Fit Regulator/flowmeter to Cylinder
USER RESPONSIBILITIES
This equipment will perform safely and reliably only
when installed, operated and maintained, and repaired in
accordance with the instructions provided. Equipment must
be checked periodically and repaired, replaced, or reset
as necessary for continued safe and reliable performance.
Defective equipment should not be used. Parts that are broken,
missing, obviously worn, distorted, or contaminated should be
replaced immediately.
The user of this equipment will generally have the sole
responsibility for any malfunction, which results from improper
use, faulty maintenance, or by repair by anyone other than an
accredited repairer.
32 | CIGWELD.COM.AU
OPERATING MANUALBLUEVENOM 4R-ROVER

Bekijk gratis de handleiding van Cigweld BlueVenom 4R-Rover, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCigweld
ModelBlueVenom 4R-Rover
CategorieNiet gecategoriseerd
TaalNederlands
Grootte11536 MB