Cigweld BlueVenom 4R-Rover handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 30 van 72
30 | CIGWELD.COM.AU
OPERATING MANUALBLUEVENOM 4R-ROVER
RIGHT CONTROL KNOB
Press to step through available options in each Process;
Once desired function selected turn clockwise to increase or
counterclockwise to decrease value
Turn the Right Control Knob to make selection or change
values and press to conrm. To select an option from the
displayed menu:
Options will be highlighted in sequence at every turn;
Turn clockwise or anti-clockwise to change selection;
Press Control Knob to conrm the selection or to enter the
next option on menu.
MIG Quickset Mode:
Inductance, Shielding Gas,
Trigger Mode (2T/4T), and Volts Trim.
MIG Manual Mode:
Inductance, Trigger Mode (2T/4T),
and Volts Trim.
ADVANCED SETTINGS MENU
In the Advanced Features Menu the Left Digital Display is
used to show the Advanced Setting selected. The Right Digital
Display shows the Advanced Setting value.
Once desired function selected use the Right Control Knob to
select or turn clockwise to increase or counterclockwise to
decrease value.
Turn the Right Control Knob to make selection or change
values and press to conrm. To select an option from the
displayed menu:
Options will be highlighted in sequence at every turn;
Turn clockwise or anti-clockwise to change selection;
Press Control Knob to conrm the selection or to enter the
next option on menu.
MENU BUTTON
Press to access Advanced Settings
(PEG) Pre Gas, (PTG) Post Gas, (BBT) Burnback, (CRF) Crater
Fill (OFF/ON), (CFT) Crater Fill Time, (CFW) Crater Fill Wire Feed
Speed, (CFU) Crater Fill Voltage, (RIN) Run In and (SPT) Spot
(2T only)
Note: Crater Fill must be turned ON to set (CFT) Crater Fill
Time, (CFW) Crater Fill Wire Feed Speed and (CFU) Crater Fill
Voltage.
Press
Forward Button to Scroll Forward in Advanced
Features and make selection
Press
Back Button to Scroll Backward in Advanced
Features and make selection
Menu Button Indicator
When illuminated the Menu for Advanced Features is activated
and the Advanced Feature is shown on the Left Digital Display
and its value on the Right Digital Display. Right Control Knob
adjusts the Advanced Feature Value selected.
DEVICE SELECTION BUTTON
Press button to select device connected.
SPOOL GUN INDICATOR
When illuminated the Spool Gun Mode has been selected. Refer
to Section 5.12.
PUSH PULL GUN INDICATOR
When illuminated the Push Pull Gun Mode has been selected.
Refer to Section 5.12.
REMOTE FEEDER (4R-ROVER) INDICATOR
When illuminated the Wirefeeder Mode has been selected.
GAS PURGE BUTTON
This purges Shielding Gas (MIG) through the MIG Gun when
pressed. When the button is pressed and released it will purge
the Shielding Gas for 15 seconds. If during that time the Gas
purge is required to be stopped press the button again.