3.04 ELECTROMAGNETIC COMPATIBILITY
WARNING
Extra precautions for Electromagnetic
Compatibility may be required when this Welding
Power Source is used in a domestic situation.
A. INSTALLATION AND USE - USERS RESPONSIBILITY
The user is responsible for installing and using the welding
equipment according to the manufacturer’s instructions.
If electromagnetic disturbances are detected then it shall
be the responsibility of the user of the welding equipment
to resolve the situation with the technical assistance of
the manufacturer. In some cases this remedial action
may be as simple as earthing the welding circuit. In other
cases it could involve constructing an electromagnetic
screen enclosing the Welding Power Source and the
work, complete with associated input lters. In all cases,
electromagnetic disturbances shall be reduced to the
point where they are no longer troublesome.
B. ASSESSMENT OF AREA
Before installing welding equipment, the user shall
make an assessment of potential electromagnetic
problems in the surrounding area. The following shall
be taken into account
1. Other supply cables, control cables, signalling and
telephone cables; above, below and adjacent to the
welding equipment.
2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of
industrial equipment.
5. The health of people around, e.g. the use of
pacemakers and hearing aids.
6. Equipment used for calibration and measurement.
7. The time of day that welding or other activities are to
be carried out.
8. The immunity of other equipment in the environment:
the user shall ensure that other equipment being used
in the environment is compatible: this may require
additional protection measures.
The size of the surrounding area to be considered
will depend on the structure of the building and other
activities that are taking place. The surrounding area
may extend beyond the boundaries of the premises.
C. METHODS OF REDUCING ELECTROMAGNETIC EMISSIONS
1. Mains Supply
Welding equipment should be connected to the
mains supply according to the manufacturer’s
recommendations. If interference occurs, it may be
necessary to take additional precautions such as
ltering of the mains supply. Consideration should
be given to shielding the supply cable of permanently
installed welding equipment in metallic conduit or
equivalent. Shielding should be electrically continuous
throughout it’s length. The shielding should be
connected to the Welding Power Source so that good
electrical contact is maintained between the conduit
and the Welding Power Source enclosure.
2. Maintenance of Welding Equipment
The welding equipment should be routinely maintained
according to the manufacturer’s recommendations.
All access and service doors and covers should be
closed and properly fastened when the welding
equipment is in operation. The welding equipment
should not be modied in any way except for
those changes and adjustments covered in the
manufacturer’s instructions. In particular, the
spark gaps of arc striking and stabilising devices
should be adjusted and maintained according to the
manufacturer’s recommendations.
3. Welding Cables
The welding cables should be kept as short as possible
and should be positioned close together, running at or
close to the oor level.
4. Equipotential Bonding
Bonding of all metallic components in the welding
installation and adjacent to it should be considered.
However Metallic components bonded to the work piece
will increase the risk that the operator could receive
a shock by touching the metallic components and the
electrode at the same time. The operator should be
insulated from all such bonded metallic components.
20 | CIGWELD.COM.AU