4.3.4 Programming mode
In actuator/function direct activation mode, pressing PRG enters programming mode, where the unit’s main operating param-
eters can be set.
If wake up navigation mode has been selected, after pressing PRG for 3 s the password needs to be entered (default 22).
If, on the other hand, locked navigation mode has been selected, pressing PRG directly accesses the basic confi guration param-
eters, such as direct commands and active alarms without needing to enter the password (if a User password other than the
default 00 has been set, the password will need to be entered), or the Service parameters (Service password required). To access
the Service parameters, go to the “PSD” menu item (see the table below) and enter the password (default 22).
Notice: the main confi guration parameters are accessed via the user terminal, for basic confi guration of the unit; for fi ne
tuning use Applica, which gives access to all the parameters available for the user profi le.
Parameter categories visible on the user terminal
The menu items available and parameters visible on the user terminal are listed below. The menu branches/parameters protect-
ed by the Service password (default 22) in locked mode are shown in bold italics.
dir (*)
(Direct
functions)
CtL
(Control)
Pro
(Display
probes)
dEF
(Defrost)
HcP
(HACCP)
CnF
(Con gura-
tion)
cMP
(Compressor)
FAn
(Fans)
ALM
(Alarms)
PSd
(***)
ESC
See the fol-
lowing table St /5 d0 rHP Hb c0 F0 A1
rd /6 dI HAn H0 c1 F1 AH/AHA
Sth /cA dP1 HFn GF1 c2 F2 AL/ALA
rdh /cb dt1 ESC GF2 c3 F3 Ad
IS (**) /cc d4 GF ESC Fd Add
r1 /nE d8 bM (****) Fpd rSA
r2 /t1 dd ESC rAL
rn /P1 ESC ESC
/4 /P2
rSC ESC
ESC
Tab. 4.d
(*) The visibility of the direct functions can be set using the corresponding parameters, and depends on whether the functions are available on the controller.
(**) Visible if there is at least one confi guration loaded on the controller (see “Appendix”)
(***) Visible as a menu item only in locked mode.
(****) Corresponds to parameter kbM
Direct functions
Acr. Description Visibility Acr. Description Visibility
BtE Enable Bluetooth™ if present Sd Defrost probe /Fb > 0
CnC Activate continuous cycle cc > 0 SHu Humidity probe /FP > 0
Eco Activate Eco mode Sm Air off probe /Fa > 0
Fr Firmware version Sr Air on probe /Fc > 0
nFE Enable copy parameters from NFC memory to control-
ler
Tab. 4.e