Carel iJW handleiding

104 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 104
21
ENG
iJW +0300103EN rel. 1.1 - 31.03.2025
Index
4.3.3 Screens
The possible states of the terminal are shown in the table below.
Wake up mode
Status Status Status
Standby/display active loads (wake
up mode)
Direct activation of loads and
functions from the keypad (wake
up mode)
Unit off (wake up mode)
Description Description Description
The display shows the main value,
alternating with any alarms and sig-
nals and active functions/actuators.
The loads can be activated or de-
activated and the direct functions
accessed from the keypad
The unit is off and can be switched
on by pressing the On/Off button
Locked mode
Status Status Status Status
In standby (locked mode) Display active loads (locked mode) Direct activation of loads and func-
tions from keypad (locked mode)
Unit off (locked mode)
Description Description Description Description
The display shows the main value,
alternating with any alarms and
signals
The terminal shows any active
loads, the keypad is locked
The loads can be activated or de-
activated and the direct functions
accessed from the keypad
The unit is off and can be switched
on by pressing On/Off . The display
shows the main value, alternating
with the message “Off
Wake up + locked mode
Status Status Status Status
Programming menu Parameter programming/display
values
Bluetooth™ connection Initial confi guration
Description Description Description Description
Scroll the programming menu
using the arrow buttons
Set the parameters using the arrow
buttons or display read-only values
The display is disabled, as the
controller is connected to an app
via Bluetooth™ Low Energy
The controller is awaiting the start
of the programming wizard
Standard display
At power on, the user terminal briefl y shows the fi rmware version and then the standard display. The standard display depends
on the setting of parameter /t1:
control temperature (control probe temperature or calculated based on two probes, see “Functions”);
value of one of the probes connected to the analogue inputs;
• control/virtual probe;
temperature set point.
Notice: if there is an active alarm, press any button to mute the buzzer.
Display active actuators/functions and direct activation of actuators/functions
If wake up navigation mode has been selected, the standard display also shows the actuators/functions that are active at that
moment. Press any button access actuator/function direct activation mode
If locked navigation mode has been selected, the standard display does not show the active actuators/functions. When pressing
any button, the display shows the message “Loc” and the icons corresponding to the currently-active actuators/functions come
on. On pressing PRG for 3 s, the display shows 3 dashes in sequence and enters actuator/function direct activation mode.