Cambium Networks cnMatrix EX2010-P handleiding
Handleiding
Je bekijkt pagina 164 van 320

L2 Features 164
l
cnMatrix(config-if)# switchport [customer-vlan <integer(1-4094)>] service-vlan <vlan_id>
l
cnMatrix(config-if)# no switchport [customer-vlan <integer(1-4094)>] [service-vlan]
If customer-vlan is not specified, the service-vlan will be applied to all incoming packets, regardless of C-
VLAN:
cnMatrix(config-if)# switchport service-vlan <vlan_id>
cnMatrix(config-if)# no switchport service-vlan <vlan_id>
cnMatrix(config-if)# switchport [customer-vlan %d] svlan-prio {<0-7> | none}
Specifies which dot1p priority to be used in the S-TAG: either a fixed user-set value, or none. If customer-
vlan is not specified, the S-VLAN-prio will be applied to all incoming packets, regardless of C-VLAN.
cnMatrix(config-if)# switchport customer-vlan pvid <vlan_id>
Specifies which C-VID value to use for untagged packets received on the customer-edge port. The
specified VLAN Id must be already configured on the port as a customer-vlan.
cnMatrix(config-if)# service-vlan <svlan> pvid <pvid>
If C-untagged packets are received on the provider port, a C-TAG needs to be added. The PVID
configured here will be the VLAN id from the C-TAG. This command is configured on the customer port,
but the value set here is applied on all network provider ports from the S-VLAN.
cnMatrix(config-if)# service-vlan <svlan> def-user-priority <value>
If C-untagged packets are received on the provider port, a C-VLAN needs to be added. The default
priority value configured here will be the dot1p used in the C-TAG. This command is configured on the
customer port, but the value set here is applied on all network provider ports from the S-VLAN.
On provider ports:
cnMatrix(config-if)# switchport egress ether-type {x8100 | x88a8 | x9100}
Specifies which TPID to be used in the S-TAG of the frames egressing on this port.
cnMatrix(config-if)# no switchport egress ether-type
Defaults which TPID to be used in the S-TAG of the frames egressing on this port.
cnMatrix(config-if)# switchport ingress ether-type {x8100 | x88a8 | x9100}
Specifies which TPID to use to determine the S-TAG of the frames ingressing on this port.
cnMatrix(config-if)# no switchport ingress ether-type
Defaults the TPID used to determine the S-TAG of the frames ingressing on this port.
cnMatrix# show provider-bridge port config
Provider Bridge Port configuration table
Port Gi0/1
Port Type : Customer-edge Port
Dot1x Protocol Tunnel Status : Peer
LACP Protocol Tunnel Status : Peer
Spanning Tree Tunnel Status : Discard
LLDP Protocol Tunnel Status : Peer
Service VLAN Classification : Customer-VLAN
Bekijk gratis de handleiding van Cambium Networks cnMatrix EX2010-P, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Cambium Networks |
| Model | cnMatrix EX2010-P |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 32421 MB |
Caratteristiche Prodotto
| Kleur van het product | Grijs |
| Gewicht | 1600 g |
| Breedte | 250 mm |
| Diepte | 210 mm |
| Hoogte | 44 mm |