Bushnell R5 handleiding
Handleiding
Je bekijkt pagina 5 van 33

5
Click to return to the Table of Contents.
› Be sure there is at least 2mm of clearance between the edges of the rings and any protruding surfaces such as the turret housing
(saddle), power selecting ring, and the flare of the objective bell. Also be sure there is at least 3mm of clearance between the
objective bell and the barrel.
› You should test position the scope for the proper eye relief. The scope rings should be left loose enough so that the scope will
slide easily. Variable power scopes should be set at the highest magnification when performing this procedure. Mount scope
onto the rifle and look through the scope in your normal shooting position.
› Test position the rifle for the proper cheek welds several times to ensure that your scope is positioned properly.
› When you are satisfied that everything is okay, mark relative positions with masking tape or similar, demount and start again.
This time, seat all screws firmly.
› The use of a torque wrench is recommended to ensure adequate fastening without over-tightening. Refer to the base and rings
user-instructions for torque values.
SIDE PARALLAX AND ILLUMINATION CONTROLS
› The inboard side-focus control ring should be set to target distance to both focus the target image and remove
parallax error.
› The outboard illumination control has 6 intensity settings with alternating off positions. If illuminating the
reticle is desired, change to an appropriate setpoint. The brightness will increase with higher numbers. Turn
the dial to any 0 position when illumination is not desired or the scope is not in use to preserve battery life.
ELEVATION AND WINDAGE TURRETS
Bushnell R5-Series scopes feature finger-adjustable audible-click elevation and windage adjustments.
1. Remove the caps from the Elevation and Windage Adjustments.
2. Grasp the turret dial and turn it in the appropriate direction indicated by the arrows. Each “click” or increment on the
Adjustment Scale Ring will change bullet impact by 1/4 Minute of Angle. 1/4 MOA corresponds to approximately 1/4 inch at 100
yards, 1/2 inch at 200 yards, etc.
VARIABLE POWER ADJUSTMENTS - MAGNIFICATION
To change magnification, rotate the Power Change Ring to align the desired number on the power scale with the index dot. When
still-hunting or stalking game, a variable scope should be set to the lowest power. You then have the widest field of view for quick
shots at close range. Higher powers should be reserved for precise long-range shots.
PRELIMINARY SIGHTING-IN
You can save a significant amount of expense and frustration by pre-sighting the scope to the rifle before you take it to the range for
zeroing.
There are two basic methods that can be used for pre-sighting your scope. Method one is to use a Bushnell® Bore Sighter (laser,
magnetic or standard). The use of a Bore Sighter saves time and ammunition and is the system most often used by gunsmiths. The
second method is traditional bore sighting:
BORE SIGHTING METHOD
1. If a rimfire rifle application, place a target at 25 to 50 yards. If it is a centerfire rifle, place the target at 50 to 100 yards.
2. Remove the bolt from the rifle.
3. Place the rifle on sandbags or a shooting rest.
4. Set the scope to its lowest magnification.
5. Peer through the bore from the receiver and adjust the position of
the rifle to center the target bull’s eye in the bore (Fig. A).
6. Without moving the rifle, look into the scope and note the position
of the reticle on the target. Remove the caps from the windage
and elevation adjustments. Adjust the windage and elevation
adjustments to center the reticle on the bull’s eye (Fig. B).
Elevation Turret Windage Turret
Fig. A
Reticle not in alignment
Fig. B
Reticle in alignment
Bekijk gratis de handleiding van Bushnell R5, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Bushnell |
| Model | R5 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 7861 MB |


