INSTALLATION, USE & CARE INSTRUCTIONS
INSTALLATION
11
PREPARE THE UNIT
all installations
1. If present, remove all protective polyfilm from the unit and/
or parts.
2. Remove the grease filter by pushing down on latch tab and
tilting the filter downward (FIG. 16). Set aside the filter.
3. Disassemble the electrical compartment cover (grey part
in FIG. 17) from inside the unit by removing its retaining
screw. Remove the parts bag behind the cover. Set aside
the parts bag and the cover along with its screw.
HD1345
FIG. 16
HD1349
SCREW
FIG. 17
HD1359
FIG. 19
HD1414
FIG. 18
4. Punch out both knock-out holes. Install an appropriate
7/8” diameter strain relief (not included, grey parts in
FIG. 18) in each hole.
NOTE: The HCK44 cord connection kit (optional) can
be used instead of the house power cable. Refer to the
instruction packed with the HCK44 cord connection kit.
horizontal exhaust installation only
5. Unplug the blower cable from its connector on faceplate.
Disassemble the faceplate from the unit by removing its
4 retaining screws (two per side, circled in FIG. 19). Set
aside the faceplate along with its screws.
6. Remove the 4 screws (two per side) retaining the blower
support plate to the top of the unit (FIG. 20). Carefully lift
out and set aside the blower with its support plate. The
blower will be reinstalled later in the unit.
HD1360
FIG. 20
SCREWS
SCREWS