22 SBI-240 Service Manual
3. When UNIT.KG is displayed, use the keys to select the piece
weight unit of measure.
4. Press the TARE/PRESET key to confirm
.
Th
e previously entered piece weight will be shown (the default value is
000000).
5. Use the keys to input a new piece weight.
6. Press and hold the SETUP key for 4 seconds to input the decimal poin
t.
7.
Press the TARE/PRESET key to confirm and return to counting mode.
3.7.2 Enter the Piece Weight with a Sample of a Known Quantity
1. Press the UNIT/DATA key.
2. When InP.PWt is displa
yed, use keys to select SPL
.PWT.
3. Press the TARE/PRESET key to access the "Get Piece Weight" mode.
4. When SPL.Lo is displayed, remove any load from the platform and pre
ss the
T
ARE/PRESET key to confirm.
If the scale hasn't stabilized, SPL.Lo will flash. After it has stabilized, it
will go to the next step.
5. When SPL.Hi is displayed, place a sample of a known quantity onto th
e scale
plat
form and press the TARE/PRESET key
.
If the scale hasn't stabilized, SPL.Hi will flash.
If the scale has stabilized, INP.PCS will be displayed quickly and the
previously entered piece weight will be displayed (the default value is
000000, and the position of decimal point is determined by CONFIG-
FUNC-PERCEN setting).
6. Use the keys to input the sample quantity.
NOTE: If the input piece weight is less than 0.5d (where d = the scale's readability,
see specifications), the indicator will display PWt.Er and will automatically return to
counting mode.
NOTE: At any time you can press ZERO/ON/OFF to exit "Get Piece Weight" and
return to counting mode.