SBI-240 Service Manual 23
7. Press the TARE/PRESET key to confirm.
8. Once an acceptable piece weight has been entered, the scale will return to
coun
ting mode.
3.8 Check Counts (count compare) in Counting Mode
The Check Counts function allows the user to enter a pre-set range. The display will
indicate whether the weighed value is within that range or indicate if it is too high or too
low.
1. Press and hold the UNIT/DATA key for 4 seconds to access the compar
ative
da
ta range.
2. HIGH will be shown and 000000 will
be displayed.
Th
e HI annunciator on the display will be lit.
3. Use the keys to input the upper limit of the range (weight, piece
quantity, or percentage depending on initial mode).
4. Press the TARE/PRESET key to confirm and move to the next step.
5. Low will be shown and 000000 will be displayed. The LO annunciator on the
display will be lit.
6. Use the keys to enter the lower limit of the range.
7. Press the TARE/PRESET key to confirm.
NOTE: If the input piece weight is less than 0.5d (where d = the scale's readability,
see specifications), the indicator will display PWt.Er and will automatically return to
counting mode.
NOTE: The piece weight that has been entered will be saved, even after powering off.
The indicator can only save one piece weight.
Entering a new piece weight will automatically replace the old one.
NOTE: If the upper limit is 0, or if it is less than or equal to the lower limit, check
weighing mode will automatically be exited.