AWT35-100109 Rev AB 11/29
If the weight oscillations exceed the HLD.RNG division range value (5 div) within the
STB.TIM time value (15 sec),
the indicator will display STB.ER. See Hold Menu.
4.1.3 Manual (Toggle) Hold Mode
When this mode is activated, the scale grabs the first stable weight reading and holds that weight on
the display until the weight returns to zero and the tare or hold button is pressed.
1. Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if
necessary.
2. Press the HOLD key to enable this function
The Hold annunciator flashes.
7. Place the item to be weighed on the scale platform
If the weight sensed is stable for STB.TIM (15 s) and above the NLD.RNG zero range (10 div
= 5 lb, 2 kg), the indicator displays the Hold mode weight. The Hold annunciator stops flashing.
3. Press the TARE key to repeat the Hold weighment or the HOLD key to exit the current mode.
If the weight is not stable within the STB.TIM time value (15 sec), the indicator displays
STB.ER. See Hold Menu.
4.2 Accumulation Function
This function can be used to record totals of individual weighments and transactions number.
The SBI 210-LCD is featured with two accumulation modes: Manual and Automatic (default).
The ACC mode can be disabled, and the mode changed in the Config Menu
.
The Automatic Acc mode is activated when the load is stable and above the NLD.RNG (10
div = 5 lb, 2kg) zero range. These settings can be changed in the Submenu 1 HOLD.
1. Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if
necessary.
2. Place the item(s) to be weighed / counted on the scale platform.
3. Press the ACC key to add up the weight/pcs to total weight/pcs and number of transactions.
4. Remove the item(s) from the scale platform and repeat the steps above for other Acc weighments.
In accumulation mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.2.1 View Totals
1. Press and hold the TOTAL key to view the current total weight/pcs and number of transactions.
2. Press the TOTAL key to exit the accumulation screen.
4.2.2 Clear Totals
1. Press and hold the TOTAL key to view the current total weight/pcs and number of transactions.
2. Press the ZERO/ON/OFF key to clear the accumulation memory and return to main screen.
3. Press the TOTAL key to exit the accumulation screen.