4 Weighing Modes
This section covers the weighing functions and modes of the SBI 210-LCD indicator.
4.1 Hold Function
This function can be used to freeze a displayed weight/pcs value. In Hold mode, the scale can capture
and hold stable weight/pcs values or average an unstable value. Then, the indicator temporarily freezes
(Hold) the value on screen for the user to view or record.
The SBI 210-LCD is featured with three hold modes: Manual, Average and Automatic (default).
The indicator provides special mode settings to accommodate weight movements in the
User Menu. Open the Submenu 1 HOLD to enable this mode and change the parameter
values: NLD.RNG (10 div), HLD.RNG (5 div), AVG.TIM (5 sec), STB.TIM (15 sec) accordingly.
4.1.1 Automatic Hold Mode (Default)
When this mode is activated, the scale automatically grabs and holds the weight on the display until
the weight returns to zero and a new Hold weighing session starts.
1. Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if
necessary.
2. Press the HOLD key to enable this function
The Hold annunciator flashes.
5. Place the item to be weighed/counted on the scale platform
If the weight sensed is above the NLD.RNG zero range (10 div = 5 lb, 2 kg) and doesn’t exceed
the HLD.RNG oscillations range (5 div = 2.5 lb, 1 kg) within the AVG.TIM average time (5 sec),
the indicator calculates and displays the Hold mode weight.
The Hold annunciator stops flashing.
3. Remove the item(s) from the scale platform and repeat the steps above for other Hold weighments.
4. Press the HOLD key to exit the current mode.
If the weight oscillations exceed the HLD.RNG division range value (5 div) within the
STB.TIM time value (15 sec),
the indicator will display STB.ER. See Hold Menu.
4.1.2 Average Hold Mode
When this mode is activated, the scale calculates accurate weight of unstable loads e.g., live animal
and holds that weight on the display until the weight returns to zero and tare or hold button is pressed.
1. Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if
necessary.
2. Press the HOLD key to enable this function
The Hold annunciator flashes.
6. Place the item to be weighed on the scale platform
If the weight sensed is above the NLD.RNG zero range (10 div = 5 lb, 2 kg) and doesn’t exceed
the HLD.RNG oscillations range (5 div = 2.5 lb, 1 kg) within the AVG.TIM average time (5 sec),
the indicator calculates and displays the Hold mode weight.
The Hold annunciator stops flashing.
3. Press the TARE key to repeat the Hold weighment or the HOLD key to exit the current mode.
The scale will automatically exit the Hold mode after the HLD.TIM time value (default, disabled).