4.3 Comparison Function
The SBI 210 Comparison mode can be used to quickly check the acceptability or unacceptability of an
item’s weight / count i.e., check-weighing / check-counting. This function is available in weighing,
percent and counting modes. Open the User Submenu 1 BEEP
to enable the audible alarm. The
COMPAR function can be disabled in the Config Menu.
1. Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if
necessary.
2. Press and hold the FUNC key for three seconds. Toggle the weighing modes by pressing the ↑
↓ keys and select either the WEIGH, PERCNT or COUNT mode.
3. Place the item(s) to be weighed/counted on the scale platform
If the weight/pieces is beyond the upper limit, the HI annunciator lights
If the weight/pieces is within the limits, the OK annunciator lights
If the weight/pieces is below the lower limit, the LO annunciator lights
4. Remove the item(s) from the platform and repeat the steps above for other Compar weighments.
In comparison mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.3.1 Setting HI / OK /LO Limits
1. In weighing or counting mode, press and hold the DATA key. Release the key when the “COMP”
message pops up. Press the TARE key to confirm.
2. The HI annunciator lights. Adjust the upper limit pressing the ↑ ↓ → keys. Press the TARE key.
3. The LO annunciator lights. Adjust the lower limit pressing the ↑ ↓ → keys. Press the TARE key
to confirm.
4. The indicator stores the limits and returns to weighing / counting mode screen.
4.4 Counting Mode [Pcs]
The SBI 210 Counting mode has been designed to allow the operator to easily carry out basic sampling
and counting routines on this scale. The COUNT mode can be disabled in the Config Menu
.
1. Power up the scale and zero the display, if necessary, by pressing the ZERO/ON/OFF key. Be
sure the scale is displaying weight in your preferred unit of measure. Press the UNIT key, if
necessary.
2. Press and hold the FUNC key for three seconds. Press the ↑ ↓ keys to navigate the options.
3. Select the COUNT option and press the TARE key to confirm.
The Pcs annunciator flashes and the last stored piece weight is recalled.
4. Place the item(s) to be counted on the scale platform.
5. The number of parts is displayed in the Pcs window.
6. Remove the item(s) from the platform and repeat the steps above for other Count weighments.
In counting mode, the function of Hold, Print, Acc, Data, Tare and, Zero keys are available.
4.4.1 Sampling – Piece Weight
1. In counting mode, press the DATA key. Release the key when the “SPL.---” message pops up.
2. Place a known quantity of items to be counted on the scale platform. Press the TARE key to confirm.
The “INP.PCS” message pops up.