AWT35-501860 Issue AE.1 Page 12
3. Scale Operation
This section covers the scale operations of simple weighing, counting and hold. The steps for various
kinds of weighing are explained in the following pages.
A warm-up time of 15 minutes is required to stabilize the measured values.
3.1. Gross Weighing
To perform a gross weighment, follow these steps:
1. Power up the scale. Be sure the scale is displaying weight in the correct unit of measure. Press
the UNITS key, if necessary to change the units of measure the scale is working in.
2. Zero the scale if necessary by pressing the ZERO key. If the weight change is within the Zero
window area the display will show 0.000. Decimal positions available may vary.
3. Place the item(s) to be weighed on the scale platform.
4. The display will now display the weight of the item that is on the weight platter
3.2. Tare Weighing
If you want to do NET weighing, such as weighing objects in a container, follow these steps:
1. Power up the scale. Be sure the scale is displaying weight in the correct unit of measure. Press
the UNITS key, if necessary to change the units of measure the scale is working in.
2. Zero the scale if necessary by pressing the ZERO key. If the weight change is within the Zero
window area the display will show 0.000. Decimal positions available may vary.
3. Place the item to be tared on the scale platform.
4. Press the TARE key. If the container weight is outside the Zero window area the display will show
0.000 weight and the NET annunciator is illuminated. Decimal positions available may vary.
5. Place the item to be weighed on the scale platform. The Net weight of the item is displayed. Press
the SELECT key to choose the Gross or Net weight.
Example: annunciators lit when tare weighing with 5 kg/lb box and 10 kg/lb of items.
3.2.1. Clear a Tare
Remove any load from the scale and press the TARE key until 0.000 is displayed. Decimal positions
available may vary.
Example: annunciators lit when clearing a 5 kg/lb container tare
3.3. Counting Mode
The SBI-110 Counting mode has been designed to allow the operator to easily carry out basic
sampling and counting routines on this scale even if the scale is mainly used for general weighing
applications. By pressing the units’ key until Pcs is illuminated on the display, the scale can now be
quickly used to sample parts ready for counting.
For count accuracy, all items should be uniform in weight and UF-5 set to HOLD 0.
It is recommended that the sample weight be a minimum of 0.1% of scale capacity.