Setting High Pass/Low Pass Parameters
High-pass filters allow signals that are higher than the specified frequency and attenuate
signals that are lower. Low-pass filters allow signals that are lower than the specified fre-
quency and attenuate signals that are higher. When combined, they are known as a band-
pass filter. Band-pass filters can be used to tailor the frequency response of a microphone
exclusively for vocals, which can be very useful in a noisy environment to filter out the
higher and lower frequencies that could mask the human vocal range during announce-
ments.
You can specify the range of frequencies that will pass through the high-pass and low-
pass filters and select the type of filter that is used through the channel’s High/Low Pass
drop-down menu option.
Ratio Sets the compression ratio to be applied to the signal.
For example, if the ratio is set for 6 (6:1), the input signal
must increase by 6 dB for the output level to increase by
1 dB.
The range is 1 to 100.
Input meter Shows the strength of the input signal.
Output meter Shows the strength of the output signal, providing a
visual indicator of the effect of the compressor on the
output signal.
Comp LED Illuminates when compression is being applied to the
signal.
Table 10. Compressor Settings