Audient EVO SP8 handleiding
Handleiding
Je bekijkt pagina 15 van 27

HARDWARE HARDWARE
Factory Reset
Clocking Congurations
A Factory Reset will return the unit to its default state and any settings will
be removed. Please note that a factory reset cannot be undone so use this
option with care.
When you are using multiple devices together with digital connections such
as ADAT, it’s vital that they all remain in sync with each other. The process of
syncing up your devices is known as ‘clocking’.
In your setup, you must choose one device to be the primary clock and all
other devices in the system will be replica clocks. It’s important that there
is only one primary clock in your system. Having multiple primary clocks will
cause the devices to go out of sync and cause distortion on your recordings.
The primary clock sends a very fast ticking signal to the replica device. This
ticking signal can either be sent via a dedicated connection for the clock,
such as the BNC Word Clock Input on the EVO SP8, or sent alongside your
audio data on an ADAT connection.
Choosing the Primary Clock Device
Channel Count per Connection
Typically, you would want to choose the device that is directly connected to the
computer to be the primary clock. This clock can then be sent to other devices
in your system using either its ADAT Outputs or a BNC Wordclock Output.
The main advantage of this is that any changes in sample rate on the computer
will automatically be sent to the other devices in the setup and everything will
remain in sync.
Otherwise, you can use the SP8 as the primary clock instead. This would send
the clock to another device via its ADAT Outputs. This can only be done on
simple setups (1x EVO SP8 and 1x EVO 16 for example) but when more devices
are involved, it’s best to make use of a BNC Word Clock connection.
At sample rates of 44.1 and 48kHz, each optical connection will carry 8 ADAT
channels. When the sample rate is increased to 88.2kHz or 96kHz, this channel
count drops due to how the ADAT protocol works. At these higher sample rates,
two TOSlink cables per connection will be required to access all 8 channels.
EVO SP8 does not support 176.4 or 192kHz sample rates.